| Measuring range | |
| option | |
| Contact Now |
ORP, or oxidation-reduction potential, is an important indicator of water quality. In the water environment, substances have their own redox properties. Substances with different redox properties interact with each other in the water, eventually causing the water body to show a certain macroscopic redox property. The ORP value can be used to reflect the macroscopic redox properties of the water body. The higher the ORP value, the stronger the oxidizing property of the water body. On the contrary, the weaker the oxidizing property. When the ORP value is negative, it means that the water body shows reducing properties. In particular, the ORP value of wastewater needs to be monitored in real time to ensure that the discharged wastewater meets standards. ASR300V online ORP electrode developed and produced by Daruifino, it can be connected to an online ORP controller to achieve continuous monitoring of water quality ORP values.
?
Monitoring the ORP value of wastewater is to evaluate the redox capacity of wastewater. The ORP value in wastewater can reflect the concentration and activity of oxidizing or reducing substances present in wastewater. By monitoring the ORP value of wastewater, harmful substances, odorous substances, bacteria and other problems existing in wastewater can be discovered in time, so that corresponding treatment measures can be taken to protect the environment and human health. In addition, monitoring the ORP value of wastewater can also evaluate the effectiveness of wastewater treatment processes. During the wastewater treatment process, changes in the ORP value can reflect the degree of organic matter removal in the wastewater and the stability of the wastewater treatment system. After the ORP electrode is connected to the online ORP controller, the data can be displayed in real time, and the wastewater treatment process can be adjusted in time based on the data to improve the efficiency and degradation effect of wastewater treatment.
?
Features
ORP composite electrode, Ag/AgCl reference electrode, double salt bridge design
The sensor is encapsulated in a reinforced ABS plastic shell and has a solid structure.
There are 1-inch NPT mounting threads at the beginning and end for easy installation.
The ORP electrode uses a flat platinum detection head, which is easy to clean.
The reference uses a large-area annular porous PTFE diaphragm with fast response.
?
Specification
| Model | ASR300V | |
| Measuring Range | -1500~1500mV | |
| Indicating electrode | platinum | |
| Reference System | Ag/AgCl reference electrode, double salt bridge, KCL gel | |
| Electrode Material | ABS+PTFE+platinum | |
| Zero(E0) | ±20mV | |
| slope(SLOP)% | >95% | |
| flow rate | 0.5m/s≥flow rate≥0.001m/s | |
| Working Pressure | 0~4bar | |
| Working Temperature | 0~60℃ continuously work | |
| Thread Size | 1-inch NPT thread | |
| Dimension | diameter 35mm, length 200mm | |

The following wastewater situations require online ORP electrodes to monitor ORP values:
Industrial wastewater treatment plant: Industrial wastewater may contain various harmful substances. Monitoring the ORP value can help evaluate the oxidation of wastewater and determine whether the wastewater meets discharge standards;
Agricultural wastewater treatment: Agricultural wastewater may contain organic matter such as pesticides and fertilizers. Monitoring the ORP value can help evaluate the oxidation of wastewater and determine the effectiveness of wastewater treatment;
Food processing wastewater treatment: Wastewater generated during food processing may contain organic matter, grease, etc. The use of ORP electrodes can help evaluate the oxidation of wastewater to determine the effectiveness of wastewater treatment.
Medical wastewater treatment: Medical wastewater may contain drug residues, pathogens, etc. Monitoring the ORP value can help determine the effectiveness of wastewater treatment.
The ORP value in wastewater is only a reference indicator, and other parameters need to be combined to comprehensively evaluate the treatment effect of wastewater. If you need to monitor other water quality parameters, please contact us. Delfino specializes in the development and production of water quality analysis instruments. Our measurement parameters include pH, ORP, conductivity, TDS, salinity, dissolved oxygen, COD, ammonia nitrogen, and turbidity. , chlorophyll, blue-green algae, residual chlorine, chlorine dioxide, etc. In addition to ORP sensors, our main products include pH ORP analyzer, conductivity analyzer, turbidity analyzer, COD analyzer, dissolved oxygen analyzer, ammonium analyzer, chlorine analyzer, etc.