Products> Dissolved Oxygen Sensor> Polarographic Dissolved Oxygen Sensor> MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe
Send Inquiry
*
*
MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe
MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe
MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe

MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe

Get Latest Price
    Share:

    Model No.MD Series Analog Dissolved Oxygen Sensor

    Description
    Product Description

    Description

    Analog dissolved oxygen sensors, also known as membrane-covered polarographic oxygen electrodes, are crucial for accurately measuring dissolved oxygen (DO) levels in various aqueous environments. These sensors, featuring a silver anode and a platinum cathode, are embedded within an insulating material. A potassium chloride electrolyte solution is separated by a permeable membrane that allows selective passage of oxygen molecules. This design ensures cost-effectiveness and enhances the sensors' applicability across diverse industries, making them indispensable tools for environmental monitoring, industrial processes, and scientific research.?

    MD300 Dissolved Oxygen Sensor & Probe Details

    ?

    Key Features of MD Series Analog Dissolved Oxygen Sensors

    • Comprehensive Model Range: The MD Series offers four distinct models - MD300, MD400, MD500, and MD600, catering to a wide spectrum of applications and requirements.
    • Extensive Measurement Capabilities: With measurement ranges extending up to 0-40 mg/L DO or 0-400% saturation, these sensors provide precise readings across a broad range of oxygen concentrations.
    • Unmatched Accuracy: Boasting a typical accuracy of ±0.3 mg/L, the MD Series ensures reliable and consistent measurements, crucial for critical applications.
    • Rapid Response Time: Featuring a fast response time of less than 30 seconds, these sensors enable real-time monitoring and quick decision-making.
    • Robust Construction: Constructed with 316L stainless steel components, the MD Series sensors are built to withstand harsh environmental conditions, ensuring long-term durability and reliability.
    • Flexible Temperature Compensation: Offering temperature compensation options with PT1000 or NTC22K, these sensors provide accurate readings across a wide temperature range, enhancing their versatility and applicability.
    Analog Dissolved Oxygen Sensor Water Quality Application
    ?

    Typical Applications

    • Water Treatment Monitoring: Essential for monitoring surface water and wastewater treatment processes, ensuring compliance with environmental standards and optimizing treatment efficiency.
    • Aquaculture and Hydroponics: Vital for maintaining optimal oxygen levels in aquaculture systems and hydroponic setups, promoting healthy growth and high yields.
    • Biopharmaceutical Fermentation Processes: Critical for monitoring and controlling oxygen levels in biopharmaceutical fermentation, ensuring product quality and consistency.
    • Environmental Research and Ecological Studies: Indispensable for studying aquatic ecosystems, assessing water quality, and understanding the impact of environmental changes on aquatic life.
    • Food & Beverage Quality Control: Important for monitoring oxygen levels in food and beverage production processes, ensuring product safety and extending shelf life.
    ?

    Important Usage Considerations

    To ensure optimal performance and longevity of your analog dissolved oxygen sensors, consider the following:

    • Regular Calibration: Perform regular calibration using zero and span points to maintain accuracy and reliability.
    • Avoid Interfering Gases: Protect sensors from exposure to interfering gases such as chlorine (Cl?) and hydrogen sulfide (H?S), which can affect measurement accuracy.
    • Maintain Proper Flow Rates: Ensure proper flow rates (0.001-0.5 m/s) to prevent membrane fouling and ensure accurate readings.
    • Protect Membrane: Safeguard the sensor membrane from oil, solvents, and sulfide contamination, which can degrade performance and shorten sensor life.
    ?

    Why Choose MD Series Sensors?

    The MD Series analog dissolved oxygen sensors offer exceptional value and performance, making them the preferred choice for a wide range of applications. Here's why:

    • High Accuracy Across Wide Temperature Ranges: Ensuring reliable measurements in diverse environmental conditions.
    • Durable Construction for Harsh Environments: Built to withstand the rigors of industrial and outdoor applications.
    • Easy Integration with Monitoring Systems: Seamlessly integrating with existing monitoring systems for real-time data acquisition and analysis.
    • Customizable Cable Lengths: Offering flexibility in installation and deployment, catering to specific application requirements.
    MD Series Analog Dissolved Oxygen Sensors & Probes

    For detailed technical specifications, ordering information, and to explore the full range of our analog dissolved oxygen sensors, visit our dedicated product page. Alternatively, contact our technical support team for personalized assistance and expert advice.

    Contact Us Now
    Enter your inquiry details, We will reply you in 24 hours.
    Please fill in the information
    * Please fill in your e-mail
    * Please fill in the content
    People who viewed this item also viewed
    Products> Dissolved Oxygen Sensor> Polarographic Dissolved Oxygen Sensor> MD Series Dissolved Oxygen Sensor with High Accuracy Polarographic Probe
    Send Inquiry
    *
    *

    We will contact you immediately

    Fill in more information so that we can get in touch with you faster

    Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

    Send